Description
- Ranging Range3-200cm
- Power supply5~36V, Operating temperature: -20 to 70
- USB serial port TTL read distance data passed
- Waterproof shell setting, anti-vibration setting, and easy to install
- Provide PC software.
Performance Parameters 1. Voltage: 5V~36V 2. Current: <38mA 3. Size: 23.2mm X 69mm 4. Fixing holes: pitch 16mm, hole radius 1mm 5. Data interface: TTL (baud rate supports 2400-921600, 115200 (default)) 6. Acquisition rate: 20Hz 7. Measuring distance: 40mm-4000mm (up to 4000mm without optical cover) 8. Ranging error: 3% of full scale Alarm connection 1. The sensor has its own hardware alarm function. You can use the host computer to set the alarm distance. When the sensor measured distance is less than the alarm threshold, the alarm line will trigger the alarm level. 2. Instructions for wiring the alarm line: When the measured distance is less than the set threshold, the alarm line generates a low-level signal. The non-alarm state is a floating state. It is recommended that the circuit use a 100K resistor to pull up. When an alarm occurs, the alarm line is pulled down to a low level. Note: If you need more sensor info, please contact me. I will share you.